SAMSUNG UE46ES6100W BN41-01812 EMMC KLM2G1HE3F-B001
samsung ue46es6100w bn41-01812 emmc klm2g1he3f-b001 bn94-05898b
TV MODEL UE46ES6100W
MAIN BOARD POWER BOARD T-CON BOARD
MAIN BOARD
MAIN BOARD MODEL BN41-01812
EMMC BIN KLM2G1HE3F-B001
ISP PIN PROGROMAR TNM5000 EMMC READ
ISP PIN READ EMMC TNM 5000
Programmer ISP Cable EMMC pin
ISP PIN 1 CMD
ISP PIN 3 RST-n(Reset) (mandatory)
ISP PIN 5 CLK (Clock)
ISP PIN 6 DAT0
ISP PIN 8, 10 VSS (GND)
Vcc of Chip Must be ON. Reset is needed only when circuit reset is not working.
Note 1: After Selecting EMMC, programmer will be switched to Report view.
because EMMC files are too large and can’t be viewed by hex editor.
you can switch back to hex editor by unmarking the report button.
Note 2: Load & Save buttons has no use in EMMC nand. you must select filename
after pressing read or program buttons. File will be saved automatically with
Boot1, Boot2, RPMB, EXT_CSD extensions for different parts of the chip.
Note 3: After pressing read or Program, EMMC size and type will automatically
be Detected.
Note 4: Use Config Window for selecting Different Parts of the chip for read and write.
Also, chip Size and name is read from the chip and can be viewed in this window.
Note 5: Erase is for total chip erase. before Programming Each part, Programmer
will erase it automatically, so no need for chip erase before program.
Note 6: Only First 192 byte of EXT_CSD is writable by users and Some of these bytes
are read-only and some parts are one-time programable so if you write over these areas,
you get Write error.
Note 7: in most cases, Reset Pin is not necessary, Power on/off the device for reset
READ EMMC
READ EMMC
READ EMMC
READ EMMC
PIN ISP PROGRAMMER RT809H READ EMMC
NR PANEL LTJ460HW05-C